BS ISO 15202-3-2004 工作场所空气.电感耦合等离子体原子发射光谱法测定气载颗粒物质中的金属和类金属物.分析

百检网 2021-07-20
标准号:BS ISO 15202-3-2004
中文标准名称:工作场所空气.电感耦合等离子体原子发射光谱法测定气载颗粒物质中的金属和类金属物.分析
英文标准名称:Workplace air - Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry - Analysis
标准类型:Z15
发布日期:2004/12/8 12:00:00
实施日期:2004/12/8 12:00:00
中国标准分类号:Z15
国际标准分类号:13.040.30
适用范围:This part of ISO 15202 specifies a procedure for the use of inductively coupled plasma atomic emission spectrometry for analysing test solutions prepared as prescribed in ISO 15202-2 from samples of airborne particulate matter collected as specified in ISO 15202-1. Method development, performance checks and a routine analysis method are specified. This part of ISO 15202 is applicable for the assessment of workplace exposure to metals and metalloids for comparison with limit values (see e.g. EN 689[1], ASTM E 1370[2], etc.). The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [3]), and for which one or more of the sample dissolution methods specified in ISO 15202-2 and the analytical procedure described in this part of ISO 15202 are applicable. However, there is no information available on the effectiveness of any of the sample dissolution methods specified in ISO 15202-2 for those elements in italics. aluminium calcium magnesium selenium tungsten antimony chromium manganese silver uranium arsenic cobalt mercury sodium vanadium barium copper molybdenum strontium yttrium beryllium hafnium nickel tantalum zinc bismuth indium phosphorus tellurium zirconium boron iron platinum thallium caesium lead potassium tin cadmium lithium rhodium titanium NOTE ISO 15202 is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1. The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2 lmin for sampling times in the range 30 min to 8 h and for assessment of exposure against the short-term exposure limits, where applicable (see 10.4). The procedure suffers from no significant spectral interferences (see 10.5), provided that suitable analytical wavelengths are used. However, inaccurate background correction and/or inadequate matrix-matching can adversely affect results.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司