UL 1441-2005 涂覆的电套管
百检网 2021-08-02
标准号:UL 1441-2005
中文标准名称:涂覆的电套管
英文标准名称:Coated electrical sleeving
标准类型:K15
发布日期:2005/9/16 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:K15
国际标准分类号:29.120.10
适用范围:1.1 The requirements of this Standard apply to Grades A and B acrylic-polymer-coated, silicone-polymer-coated, or vinyl-polymer-coated electrical sleeving that consists of closely woven fabric made from glass (see Table 1 for materials and ratings) and intended for use in equipment designed to be installed and used in accordance with the rules of the Canadian Electrical Code, Part I (CEC), or ANSI/NFPA 70, National Electrical Code (NEC). A product for use at temperatures greater than indicated in Clause 1.2 or a different polymer coating or fibre may be acceptable provided that (a) it meets the performance tests in this Standard; and (b) long-term heat-aging tests are conducted as covered in UL 746B or CAN/CSA-C22.2 No 0.17, using dielectric strength as a primary property and flammability as a secondary property. 1.2 These requirements apply to coated electrical sleeving having a standard temperature index classification of 105, 130, 155, 180, 200, 220, and 240 鳦. 1.3 These requirements apply to coated electrical sleeving intended for use in connection with the internal wiring of electrical devices and appliances located in dry or damp locations where it is not feasible to employ a standard insulated conductor, such as appliance-wiring material, specifically intended for the purpose. Coated electrical sleeving is intended for insulating one or more uninsulated or partially insulated conductors, bus bars, component leads, or assemblies of electrical components. Coated electrical sleeving may be employed in equipment where it is not subjected to repeated flexing or severe mechanical stress. 1.4 These requirements apply to oil-resistant coated electrical sleeving intended for occasional or intermittent contact with oil. 1.5 These requirements do not apply to unimpregnated or uncoated fabric sleeving, which is generally not considered acceptable for sole (functional) insulation because of the openings inherent in the weave construction of the sleeving fabric. 1.6 These requirements do not apply to tubing extruded with reinforcement, extruded electrical tubing, or tubing intended only for mechanical protection, since they are covered by other requirements. 1.7 These requirements do not apply to coated electrical sleeving when it is employed as splice insulation in an insulation system above 105 鳦 (Class A) operation. This new edition of ANSI/UL 1441, harmonized with CSA, includes the following changes in requirements: 1. Test Method for Volume Resistivity, 2. Flame Test Equipment Standardization, 3. Removal of the Option of Using ASTM No. 2 Oil, 4. Clarification of Number of Samples to be tested, 5. Product/Package Marking Requirements, 6. Summary of Products Covered, 7. Type of Air-Circulating Oven Defined.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;