BS EN 61558-2-13-2009 电压<1100 V用变压器.电抗器.电源装置及类似设备的安全性.自动变压器用专用要求和并入自动变压器的电源装置

百检网 2021-08-05
标准号:BS EN 61558-2-13-2009
中文标准名称:电压<1100 V用变压器.电抗器.电源装置及类似设备的安全性.自动变压器用专用要求和并入自动变压器的电源装置
英文标准名称:Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers
标准类型:K41
发布日期:2009/9/30 12:00:00
实施日期:2009/9/30 12:00:00
中国标准分类号:K41
国际标准分类号:29.180
引用标准:IEC 61558-1-2005
适用范围:Replacement:This part of IEC 61558 deals with the safety of auto transformers for general applicationsand power supply units incorporating auto transformers for general applications.Transformers incorporating electronic circuits are also covered by this standard.NOTE 1 Safety includes electrical, thermal and mechanical aspects.Unless otherwise specified, from here onward, the term transformer covers autotransformers for general applications and power supply units incorporating autotransformers for general applications.NOTE 2 : For power supply units (linear) this part is applicable. For switch mode power supply units, IEC 61558-2-16 isapplicable together with this part.This part is applicable to stationary or portable, single-phase or polyphase, air-cooled(natural or forced) independent or associated dry- type transformers. The windings may beencapsulated or non-encapsulated.The rated supply voltage does not exceed 1 100 V a.c., and the rated supply frequencyand the internal operating frequencies do not exceed 500 Hz.The core power does not exceed:– 2 kVA for single-phase transformers;– 10 kVA for polyphase transformers.The rated output does not exceed:– 40 kVA for single-phase transformers;– 200 kVA for polyphase transformers.This part is applicable to transformers without limitation of the core power and the ratedoutput both being subject to an agreement between the purchaser and the manufacturer.Where applicable, the no-load output voltage or the rated output voltage does not exceed1 000 V a.c. or 1 415 V ripple-free d.c., and for independent transformers, the no-loadoutput voltage and the rated output voltage exceeds 50 V a.c., or 120 V ripple-free d.c.This part is not applicable to external circuits and their components intended to be connectedto the input terminals and output terminals of the transformers.Transformers covered by this part are used only in applications where no insulationbetween circuits is required by the installation rules or by the end product standard.NOTE 3 Attention is drawn to the following:– for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (fromother applicable standards, national rules, etc.) may be necessary;– measures to protect the enclosure and the components inside the enclosure against external influences suchas fungus, vermin, termites, solar-radiation, and icing should also be considered;– the different conditions for transportation, storage, and operation of the transformers should also beconsidered;– additional requirements in accordance with other appropriate standards and national rules may be applicable totransformers intended for use in special environments.NOTE 4 Future technological development of transformers may necessitate a need to increase the upper limit ofthe frequencies, until then this part may be used as a guidance document.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司