DIN EN 1047-1-2006 安全存储装置.耐火性能的分类和试验方法.第1部分:数据保险箱和磁盘衬套

百检网 2021-07-15
标准号:DIN EN 1047-1-2006
中文标准名称:安全存储装置.耐火性能的分类和试验方法.第1部分:数据保险箱和磁盘衬套
英文标准名称:Secure storage units - Classification and methods of test for resistance to fire - Part 1: Data cabinets and diskette inserts; English version of DIN EN 1047-1:2006
标准类型:L64;C67
发布日期:1999/12/31 12:00:00
实施日期:2006/1/1 12:00:00
中国标准分类号:L64;C67
国际标准分类号:13.310
引用标准:EN 1363-1-1999;EN 60584-1;EN 61515
适用范围:This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts.Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature andhumidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Twolevels of fire severity (S 60 and S 120) based upon time of fire exposure: and three protechon classes (P, D andDIS) are specified using the maximum temperature increases and humidity values permitted within the storagespace of the data cabinet.Diskette inserts (BI 60 P/DIS and DI 120 P/DIS) are installed in data cabinets of protection class S 60 P or S 120 P.respectively, and subjected to a fire endurance test (see 5.1.2).Requirements are also specified for test specimens, the technical documentation for the test specimen, correlationof the test specimen with the technical documentation, preparation for type testing and test procedures.A scheme to classify the fire resisting data cabinets and diskette inserts from the test results is also given (seeTable 1 ).Cabinets having the same design, protection and construction features (type and thickness of construction andprotective materials, rebate geometry, locking, etc.) will only give the same fire protection classification as that of atest specimen if they are of similar internal dimensions. The maximum difference in internal dimensions (height,width and depth of the storage space, measured from wall to wall) to which the test classification could apply is +15 %. Cabinets having internal dimensions which differ by more than this amount from that of the tested specimenshould be submitted to an extra test.The wall, ceiling and door thicknesses should not be below the specified minimum limit of the type-tested thicknessby more than 3 %.Diskette inserts should only be installed in data cabinets having the same design as the series of protection class S60 P and S 120 P, respectively, in which the insert has been tested in accordance with 5.1.2. Where several insertsare installed, they should be built in one beside the other or one above the other from bottom to top, respectively.The volume and total height of the installed inserts should not exceed 50 % of the total internal volume or 50 % ofthe internal height, respectively, of the data cabinets into which they are installed. The dimensions of the insert canbe adapted by increasing the width and depth to the corresponding dimensions of the data cabinets. A reduction ofthese dimensions as well as a change of the height is only admitted within the specified tolerance.The temperature increases during type-tests on data cabinets and diskette inserts will be considered in decidingthe permitted diskette insert installations. For a permitted installation, the temperature increase of the intended datacabinet (ATa K) should not exceed the temperature increase of the tested data cabinet (ATb K) in which thediskette insert has been type-tested by more than the difference between the maximum value for the diskette insert(ATi K) and the maximum admissible temperature increase (30 K), i.e: ATa -ATb < 30 K - ATi (See example inAnnex B).A description of the installation of the diskette inserts should be given in the technical documentation of themanufacturer.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
相关问答