IEC 61660-2-1997 电厂与变电站直流辅助设施中的短路电流 第2部分:效应计算

百检网 2021-07-16
标准号:IEC 61660-2-1997
中文标准名称:电厂与变电站直流辅助设施中的短路电流 第2部分:效应计算
英文标准名称:Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2: Calculation of effects
标准类型:F20
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:F20
国际标准分类号:29.240.01
适用范围:This part of IEC 61660 describes a method for calculation of the mechanical and thermal effects on rigid conductors caused by short-circuit currents in d.c. auxiliary installations in power plants and substations. Such systems may contain the following items of equipment which act as sources, as well as contributing to the short-circuit currents: - rectifiers in three-phase a.c. bridge connection for 50 Hz; - stationary lead-acid batteries; - smoothing capacitors; - d.c. motors with independent excitation. This standard provides a method which has wide application, and which gives results of sufficient accuracy. The calculation method is based on substitute functions, which cause approximately 1he same maximum stresses in the conductors and the same forces on the supports as the actual electromagnetic force. The standardized calculation procedures of clauses 2 and 3 are applicable for the electromagnetic effect on rigid conductors and the thermal effect on bare conductors and electrical equipment, respectively. For cables and insulated conductors, however, reference is made to IEC 60949 and IEC 60986, for example. Only d.c. auxiliary installations in power plants and substations are dealt with in this standard. In particular, the following points should be noted: - The calculation of short-circuit currents should be based on IEC 61660-1. - Short-circuit duration used in this standard depends on the protection concept, and should be considered in that sense. - These standardized procedures are adjusted to practical requirements, and contain simplifications with safety margins. Testing or more detailed methods of calculation or both may be used. - In clause 2 of this standard, only the stresses caused by short-circuit currents are calculated. Furthermore, other stresses can exist, such as those caused by dead-load, operating forces, or earthquakes. The combination of these loads with the short-circuit loading should be part of an agreement and/or given by standards, for example erection codes.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
相关问答