DIN EN 1993-4-2-2017 欧洲法规3:钢结构设计.第4-2部分:槽罐.德文版本EN 1993-4-2-2007+AC-2009+A1-2017

百检网 2021-07-31
标准号:DIN EN 1993-4-2-2017
中文标准名称:欧洲法规3:钢结构设计.第4-2部分:槽罐.德文版本EN 1993-4-2-2007+AC-2009+A1-2017
英文标准名称:Eurocode 3: Design of steel structures - Part 4-2: Tanks; German version EN 1993-4-2:2007 + AC:2009 + A1:2017
标准类型:P26
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:P26
国际标准分类号:23.020.10;91.010.30;91.080.13
引用标准:EN 1090-2008;EN 1990-2002;EN 1991-1996;EN 1991-1;EN 1991-1-2-2002;EN 1991-1-3-2003;EN 1991-1-4-2005;EN 1991-1-5-2003;EN 1991-1-6-2005;EN 1991-1-7-2006;EN 1991-4-2006;EN 1993-1-1-2005;EN 1993-1-3-2006;EN 1993-1-4-2006;EN 1993-1-6-2007;EN 1993-1-7-2007;EN 1
适用范围:(1) Part 4-2 of Eurocode 3 provides principles and application rules for the structural design of vertical cylindrical, conical and pedestal above ground steel tanks for the storage of liquid products with the following characteristics: a) tanks with capacity greater than 100 m3 (100000 l); b) tanks that have significant fabrication or assembly on site; c) shop-fabricated tanks with conical bottoms, supported on skirts or columns; d) tanks with characteristic internal pressures above the liquid surface not more negative than -0,1 bar and not greater than 0,5 bar; e) design metal temperatures limited to the ranges: 1) tanks constructed using structural steel grades, -50 °C >T < +300 °C; 2) tanks constructed using austenitic stainless steels, -165 °C > T < +300 °C; 3) tanks constructed with special steel grades that have defined yield strengths up to higher temperatures, -165 °C > T < the maximum defined temperature for the grade; 4) tanks susceptible to failure by fatigue, T < 150 °C; f) in cylindrical ground-supported tanks, the maximum design liquid level not higher than the top of the cylindrical shell. (2) This Part 4-2 is concerned only with the requirements for resistance and stability of steel tanks. Other design requirements are covered by EN 14015 for ambient temperature tanks and by EN 14620 for cryogenic tanks, and by EN 1090 for fabrication and erection considerations. These other requirements include foundations and settlement, fabrication, erection and testing, functional performance, and details like man-holes, flanges, and filling devices. (3) Provisions concerning the special requirements of seismic design are provided in EN 1998-4 (Eurocode 8 Part 4 Design of structures for earthquake resistance: Silos, tanks and pipelines), which complements the provisions of Eurocode 3 specifically for this purpose. (4) The design of a supporting structure for a tank is dealt with in EN 1993-1-1. (5) The design of an aluminium roof structure on a steel tank is dea

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
相关问答