BS EN 60909-3-2010 三相交流系统中的短路电流.两条独立线路同时对地短路和部分短路电流流入大地时的电流

百检网 2021-07-31
标准号:BS EN 60909-3-2010
中文标准名称:三相交流系统中的短路电流.两条独立线路同时对地短路和部分短路电流流入大地时的电流
英文标准名称:Short-circuit currents in three-phase a.c systems - Currents during two separate simultaneous line-to-earth short-circuits and partial short-circuit currents flowing through earth
标准类型:K04
发布日期:2010/4/30 12:00:00
实施日期:2010/4/30 12:00:00
中国标准分类号:K04
国际标准分类号:17.220.01;29.020;29.240.20
适用范围:This part of IEC 60909 specifies procedures for calculation of the prospective short-circuitcurrents with an unbalanced short circuit in high-voltage three-phase a.c. systems operatingat nominal frequency 50 Hz or 60 Hz, i. e.:a) currents during two separate simultaneous line-to-earth short circuits in isolated neutral orresonant earthed neutral systems;b) partial short-circuit currents flowing through earth in case of single line-to-earth shortcircuit in solidly earthed or low-impedance earthed neutral systems.The currents calculated by these procedures are used when determining induced voltages ortouch or step voltages and rise of earth potential at a station (power station or substation) andthe towers of overhead lines.Procedures are given for the calculation of reduction factors of overhead lines with one or twoearth wires.The standard does not cover:a) short-circuit currents deliberately created under controlled conditions as in short circuittesting stations, orb) short-circuit currents in the electrical installations on board ships or aeroplanes, orc) single line-to-earth fault currents in isolated or resonant earthed systems.The object of this standard is to establish practical and concise procedures for the calculationof line-to-earth short-circuit currents during two separate simultaneous line-to-earth shortcircuits and partial short-circuit currents through earth, earth wires of overhead lines andsheaths or shields of cables leading to conservative results with sufficient accuracy. For thispurpose, the short-circuit currents are determined by considering an equivalent voltagesource at the short-circuit location with all other voltage sources set to zero. Resistances ofearth grids in stations or footing resistances of overhead line towers are neglected, whencalculating the short-circuit currents at the short-circuit location.This standard is an addition to IEC 60909-0. General definitions, symbols and calculationassumptions refer to that publication. Special items only are defined or specified in thisstandard.The calculation of the short-circuit currents based on the rated data of the electricalequipment and the topological arrangement of the system has the advantage of beingpossible both for existing systems and for systems at the planning stage. The procedure issuitable for determination by manual methods or digital computation. This does not excludethe use of special methods, for example the super-position method, adjusted to particularcircumstances, if they give at least the same precision.As stated in IEC 60909-0, short-circuit currents and their parameters may also be determinedby system tests.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
相关问答