BS EN ISO 80601-2-61-2011 医用电气设备.对脉搏血氧计设备基本安全和基本性能的特殊要求
百检网 2021-07-31
标准号:BS EN ISO 80601-2-61-2011
中文标准名称:医用电气设备.对脉搏血氧计设备基本安全和基本性能的特殊要求
英文标准名称:Medical electrical equipment. Particular requirements for basic safety and essential performance of pulse oximeter equipment
标准类型:C38
发布日期:2011/8/31 12:00:00
实施日期:2011/8/31 12:00:00
中国标准分类号:C38
国际标准分类号:11.040.55
引用标准:IEC 60068-2-31-2008;IEC 60529-2001;IEC 60601-1-2-2007;IEC 60601-1-6-2010;IEC 60601-1-8-2006;IEC 60825-1-2007;ISO 7000/IEC 60417-2004;ISO 14155-2011;ISO 14937-2000;ISO 15223-1-2007;IEC 60068-2-27-2008;IEC 60068-2-64-2008;IEC 60601-1-9-2007;IEC 60601-1-10-2
适用范围:Subclause 1.1 of The general standard is replaced by:This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETEREQUIPMENT intended for use on humans, hereafter referred to as ME EQUIPMENT. This includes any part necessaryfor NORMAL USE, including the PULSE OXIMETER MONITOR, PULSE OXIMETER PROBE, and PROBE CABLE EXTENDER.These requirements also apply to PULSE OXIMETER EQUIPMENT, including PULSE OXIMETER MONITORS, PULSEOXIMETER PROBES and PROBE CABLE EXTENDERS, which have been REPROCESSED.The intended use of PULSE OXIMETER EQUIPMENT includes, but is not limited to, the estimation of arterial oxygenhaemoglobin saturation and pulse rate of PATIENTS in professional healthcare institutions as well as PATIENTSin the HOME HEALTHCARE ENVIRONMENT.This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended for use in laboratoryresearch applications nor to oximeters that require a blood sample from the PATIENT.If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only,the title and content of that clause or subclause will say so. If that is not the case, the clause or subclauseapplies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope ofthis standard are not covered by specific requirements in this standard except in 201.11 and in 7.2.13 and8.4.1 of the general standard.NOTE See also 4.2 of the general standard.This standard can also be applied to PULSE OXIMETER EQUIPMENT and their ACCESSORIES used forcompensation or alleviation of disease, injury or disability.This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended solely for foetal use.This International Standard is not applicable to remote or slave (secondary) devices that display SpO2 valuesthat are located outside of the PATIENT ENVIRONMENT.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;