IEC/TR3 61852-1998 医用电气设备 医用数字成像和通信(DICOM) 放射治疗设备

百检网 2021-08-02
标准号:IEC/TR3 61852-1998
中文标准名称:医用电气设备 医用数字成像和通信(DICOM) 放射治疗设备
英文标准名称:Medical electrical equipment - Digital imaging and communications in medicine (DICOM) - Radiotherapy objects
标准类型:C30
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:C30
国际标准分类号:11.040.50
适用范围:This report specifies the following information objects: 1) A DICOM Image Information Object for Radiotherapy. It specifies the semantic content of RT Images. It is commonly abbreviated to the RT Image IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Image IOD is radiotherapy images which have been obtained on a conic imaging geometry, such as that found on conventional simulators and portal imaging devices. It can also be used for calculated images using the same geometry, such as digitally reconstructed radiographs (DRRs). 2) A DICOM Dose Information Object for Radiotherapy. It specifies the semantic content of RT Doses. It is commonly abbreviated to the RT Dose IOD, It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Dose IOD is radiotherapy dose distributions which have been calculated on a radiotherapy treatment planning system, represented as two- or three-dimensional dose grids, groups of named or unnamed dose points, isodose curves, and dose-volume histograms (DVHs). 3) A DICOM Structure Set Information Object for Radiotherapy. It specifies the semantic content of RT Structure Sets. It is commonly abbreviated to the RT Structure Set IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Structure Set IOD is radiotherapy patient-related structures which have been identified on devices such as CT scanners, virtual simulation workstations, or treatment planning systems. 4) A DICOM Plan Information Object for Radiotherapy. It specifies the semantic content of RT (Treatment) Plans. It is commonly abbreviated to the RT Plan IOD. It also includes the corresponding Storage SOP Class so that this IOD can be used in Network and Media Storage exchanges. The scope of the RT Plan IOD is geometric and dosimetric data specifying a course of external beam and/or brachytherapy treatment. This report includes a number of addenda to existing Parts of DICOM; therefore the reader should have a working understanding of the Standard. 1. Part 3 Addenda (Extension to the body, Annex A, B, C and D) 2. Part 4 Addenda (Extension to Annex B) 3. Part 6 Addenda (Extension to Section 6 and Annex A) Add to Section 2

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
相关问答