标准号:ANSI/ASTM E2557-2007
中文标准名称:地震尽职评估用*大可能损失(pml)评估的实施规程
英文标准名称:Practice for Probable Maximum Loss (pml) Evaluations for Earthquake Due-diligence Assessments
标准类型:A11
发布日期:2007/5/15 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:A11
国际标准分类号:03.060
适用范围: This practice establishes standard-of-care for evaluation and classification of the financial risks from earthquake damage to real estate improvements for use in financial transactions. As such, this practice permits a user to satisfy, in part, their real estate transaction due-diligence requirements with respect to assessing and characterizing a property's potential losses from earthquakes. This practice is intended to address only physical damage to the property from site and building response. Hazards addressed in this practice include earthquake ground shaking, earthquake-caused site instability, including faulting, subsidence, settlement landslides and soil liquefaction, earthquake-caused tsunamis and seiches, and earthquake-caused flooding from dam or dike failures. Earthquake-caused fires and toxic materials releases are not hazards considered in this practice. This practice does not purport to provide for the preservation of life safety, or prevention of building damage associated with its use, or both. This practice does not address requirements of any federal, state, or local laws and regulations of building construction or maintenance. Users are cautioned that current federal, state, and local laws and regulations may differ from those in effect at the times of construction or modification of the building(s), or both. This practice does not address the contractual and legal obligations between prior and subsequent Users of PML reports or between providers who prepared the report and those who would like to use such prior reports. This practice does not address the contractual and legal obligations between a provider and a user, and other parties, if any. It is the responsibility of the owner of the building(s) to establish appropriate life-safety and damage prevention practices and determine the applicability of current regulatory limitations prior to use. Considerations not included in the scope: the impacts of damage to building contents, loss of income(s), rents, or other economic benefits of use of the property, or from legal judgments, fire sprinkler water-induced damage or fire. The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.