标准号:IEC 60034-3-2007
中文标准名称:旋转电机.第3部分:用蒸汽涡轮机或燃气涡轮机驱动的同步发电机用特殊需求
英文标准名称:Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines
标准类型:K20
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:K20
国际标准分类号:29.160.20
引用标准:IEC 60034-1;IEC 60034-4;IEC 60045-1;IEC 60079
适用范围:This part of IEC 60034 applies to three-phase synchronous generators, having rated outputsof 10 MVA and above driven by steam turbines or combustion gas turbines. It supplementsthe basic requirements for rotating machines given in IEC 60034-1.Common requirements are prescribed together with specific requirements for air, for hydrogenor for liquid cooled synchronous generators.This part of IEC 60034 also gives the precautions to be taken when using hydrogen cooledgenerators including:– rotating exciters driven by synchronous generators;– auxiliary equipment needed for operating the generators;– parts of the building where hydrogen might accumulate.NOTE 1 These requirements also apply to a synchronous generator driven by both a steam turbine and acombustion gas turbine as part of a single shaft combined cycle unit.NOTE 2 These requirements do not apply to synchronous generators driven by water (hydraulic) turbine or windturbine.NOTE 3 The precautions to be taken when using hydrogen are valid for all cases where hydrogen is used as acoolant.