ISO 7235-2003 声学.管道消音器和空气界面装置的实验室测量步骤.插入损失、流动噪声和总压损失

百检网 2021-08-02
标准号:ISO 7235-2003
中文标准名称:声学.管道消音器和空气界面装置的实验室测量步骤.插入损失、流动噪声和总压损失
英文标准名称:Acoustics - Laboratory measurement procedures for ducted silencers and air-terminal units - Insertion loss, flow noise and total pressure loss
标准类型:Z32
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:Z32
国际标准分类号:91.120.20
适用范围:This International Standard specifies methods for determining — the insertion loss, in frequency bands, of ducted silencers with and without airflow, — the sound power level, in frequency bands, of the flow noise (or regenerated sound) generated by ducted silencers, — the total pressure loss of silencers with airflow, and — the transmission loss, in frequency bands, of air-terminal units. The measurement procedures are intended for laboratory measurements at ambient temperature. Measurements on silencers in situ are specified in ISO 11820. It is to be noted that the results determined in a laboratory according to this International Standard will not necessarily be the same as those obtained in situ (installation), as different sound and flow fields will yield different results. For example, the pressure loss will be lower under laboratory conditions than in situ, but will be comparable between different laboratories. This International Standard is applicable to all types of silencer including silencers for ventilating and air-conditioning systems, air intake and exhaust of flue gases, and similar applications. Other passive air-handling devices, such as bends, air-terminal units or T-connectors, can also be tested using this International Standard. This International Standard is not applicable to reactive silencers used for motor vehicles. NOTE 1 Annex A specifies the sound field excitation equipment. Annex B gives requirements for the transition element. Annex C gives details of duct walls and limiting insertion loss. Annex D specifies how to convert one-third-octave band attentuation values to octave band values. Annex E gives requirements for measurements on large parallel-baffle silencers. Annex F specifies a test of longitudinal attenuation. Annex G gives guidelines on anechoic terminations and Annex H shows examples of measurement arrangements. NOTE 2 Acoustic testing of air-terminal devices and fan-coil units is to be carried out as described for air-terminal units. NOTE 3 Sound power measurements on air-terminal units are specified in ISO 5135. Measurements of the pressure loss of air-terminal units are described in EN 12238, EN 12239 and EN 12589.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司