ISO 16063-15-2006 振动和冲击传感器的校准方法.第15部分:用激光干涉法的初级角振动校准
百检网 2021-08-04
标准号:ISO 16063-15-2006
中文标准名称:振动和冲击传感器的校准方法.第15部分:用激光干涉法的初级角振动校准
英文标准名称:Methods for the calibration of vibration and shock transducers - Part 15: Primary angular vibration calibration by laser interferometry
标准类型:L15
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:L15
国际标准分类号:17.160
适用范围:This part of ISO 16063 specifies the instrumentation and procedures used for primary angular vibrationcalibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotationalangle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complexsensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in this part ofISO 16063 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angulartransducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angularacceleration.It is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to1 000 rad/s2 (frequency-dependent).These ranges are covered with the uncertainty of measurement specified in Clause 3. Calibration frequencieslower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) andangular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3Bspecified in this part of ISO 16063, in conjunction with an appropriate low-frequency angular vibrationgenerator.Method 1A (cf. Clause 8: fringe-counting, interferometer type A) and method 1B (cf. Clause 8: fringe-counting,interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequencyrange of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (cf. Clause 9:minimum-point method, interferometer type A) and method 2B (cf. Clause 9: minimum-point method,interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to1,6 kHz. Method 3A (cf. Clause 10: sine-approximation method, interferometer type A) and method 3B(cf. Clause 10: sine-approximation method, interferometer type B) can be used for magnitude of sensitivityand phase calibration in the frequency range of 1 Hz to 1,6 kHz. Methods 1A, 1B and 3A, 3B provide forcalibrations at fixed angular acceleration amplitudes at various frequencies. Methods 2A and 2B requirecalibrations at fixed rotational angle amplitudes (angular velocity amplitude and angular accelerationamplitude vary with frequency).
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;