IEC 61326-3-2-2008 测量、控制和实验室用电气设备.电磁兼容性(EMC)的要求.第3-2部分:与安全相关的系统和用于与执行安全相关的功能设备(功能安全)用抗扰度要求.带指定电磁环境的工
百检网 2021-07-15
标准号:IEC 61326-3-2-2008
中文标准名称:测量、控制和实验室用电气设备.电磁兼容性(EMC)的要求.第3-2部分:与安全相关的系统和用于与执行安全相关的功能设备(功能安全)用抗扰度要求.带指定电磁环境的工业设施
英文标准名称:Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety related functions (functional safety) - Industrial applications w
标准类型:K60
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:K60
国际标准分类号:25.040.40;33.100.20
引用标准:IEC 60050-161;IEC 61000-4-2-2001;IEC 61000-4-3-2006;IEC 61000-4-4-2004;IEC 61000-4-5-2005;IEC 61000-4-6-2004;IEC 61000-4-8-1993;IEC 61000-4-11-2004;IEC 61000-4-29-2000;IEC 61000-6-2-2005;IEC 61326-1-2005;IEC 61326-2-1-2005;IEC 61326-2-2-2005;IEC 61326-2-3
适用范围:The scope of IEC 61326-1 applies to this part of IEC 61326 but is limited to systems andequipment for industrial applications within a specified electromagnetic environment andintended to perform safety functions as defined in IEC 61508 with SIL 1-3.The electromagnetic environments encompassed by this product family standard areindustrial, both indoor and outdoor, as they can be found in industrial applications with anelectromagnetic environment having specified characteristics (for example, process industry).The difference between the electromagnetic environment covered by this standard comparedto the general industrial environment (see IEC 61326-3-1) is due to the mitigation measuresemployed against electromagnetic phenomena leading to a specified electromagneticenvironment.The environment of industrial application with a specified electromagnetic environmenttypically includes the following characteristics:– industrial area with limited access;– limited use of mobile transmitter;– dedicated cables for power supply and control, signal or communication lines;– separation between power supply and control, signal or communication cables;– factory building mostly consisting of metal construction;– overvoltage/lightning protection by appropriate measures (for example, metal constructionof the building or use of protection devices);– pipe heating systems driven by a.c. main power may be present;– no high-voltage substation close to sensitive areas;– presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with lowpower;– competent staff;– periodical maintenance of equipment and systems;– mounting and installation guidelines for equipment and systems.A more detailed description of the above-mentioned typical characteristics is given inAnnex B.Equipment and systems considered as “proven-in-use” according to IEC 61508 or IEC 61511are excluded from the scope of IEC 61326-3-2.Fire alarm systems and security alarm systems intended for protection of buildings areexcluded from the scope of IEC 61326-3-2.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;