IEC 61970-405-2007 能量管理系统应用程序接口(EMS-API).第405部分:通用事项记录和订阅(GES)

百检网 2021-07-15
标准号:IEC 61970-405-2007
中文标准名称:能量管理系统应用程序接口(EMS-API).第405部分:通用事项记录和订阅(GES)
英文标准名称:Energy management system application program interface (EMS-API) - Part 405: Generic eventing and subscription (GES)
标准类型:L78
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:L78
国际标准分类号:33.200;35.240.50
引用标准:IEC 61970-1-2005;IEC/TS 61970-2;IEC 61970-301-2005;IEC 61970-401;IEC 61970-402;Data Acquisition from Industrial Systems section Alarms and Events (DAIS A&E), OMG;Utility Management System (UMS) Data Access Facility (DAF), OMG Adopted Specification,;OPC Al
适用范围:The IEC 61970-405 Generic Eventing and Subscription (GES) specification specifies ageneralized interface for efficient exchange of messages. The specification takes into accountthe latencies caused by a Local Area Network (LAN) providing efficient data exchange alsoover Local Area Networks. The Generic Eventing and Subscription (GES) API is expected toprovide one of the primary means for accomplishing application integration. Beyond the scopeof the GES API, other APIs address the high performance, real-time interactive needs of anapplication within a running system as well as request/reply oriented generic data access.IEC 61970-405 is derived from the Object Management Group (OMG) Data Acquisition fromIndustrial Systems section Alarms and Events (DAIS A&E) specification. OMG DAIS A&Erelies on the OMG Data Access Facility (DAF) and OPC Alarms and Events (A&E)specifications. OMG DAIS A&E is a Platform Specific Model (PSM) with CORBA as theplatform and OPC A&E is a PSM with Microsoft COM as the platform. Implementers wantingan introduction to OMG DAIS A&E and OPC A&E shall read these documents.The GES interface is intended to interoperate with other IEC 61970 based interfaces. Hence itis possible to use information retrieved from other interface to access the same informationusing this interface, for example:• object identifiers,• attribute names or identifiers,• class names or identifiers.The way data is organized in a server implementing the GES interface can be seen by usingthe browse interfaces for data and meta data. It is also possible to use the data accessinterface directly without using the browse interfaces if the client has an a priori knowledge ofobject, class and attribute identifiers. Object identifiers may be retrieved using data from otherinterfaces, for example a CIMXML file or the IEC 61970-404 interface. Information on whatclasses and attributes are available will be described in IEC 61970-45X documents.IEC 61970-405 describes the functionality in a technology independent way, it is a PlatformIndependent Specification (PIM). Hence, it explains the functionality to a level that can beused to create PSMs or be an introduction to existing PSMs, i.e. DAIS A&E and OPC A&E.Implementers wanting an introduction to OMG DAIS A&E and OPC A&E should read thesedocuments.IEC 61970-405 consists of two parts:• SCADA alarms and events that is the Platform Independent Specification (PIM) derivedfrom DAIS A&E and OPC A&E. This part is called “Generic Eventing and SubscriptionAlarms and Events” (GES A&E).• Generic messaging that is a generalization of the SCADA alarms and events. This part isjust called “Generic Eventing and Subscription” (GES).IEC 61970-1 provides the EMS-API reference model upon which this standard is based. Inthat reference model, the terminology used in this part of IEC 61970 is introduced and the roleof the CIS is explained.IEC 61970-401 provides an overview and framework for the CIS (IEC 61970-4XX)standards.IEC 61970-402 provides the base services to be used in conjunction with otherIEC 61970-4XX documents. This specification extends the Common Services to provide anevent subscription oriented mechanism for applications to exchange CIM data.The mapping of IEC 61970-405 to implementation specific technologies or Platform SpecificModels (PSMs) is further described in a separate series of documents, i.e. the futureIEC 61970-5XX. For actual implementations, the future IEC 61970-5XX, OMG DAIS A&E,OMG DAF or OPC A&E are used.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司