BS ISO 16063-15-2006 振动和冲击传感器的校准方法.用激光干涉测量法进行初级振动角校准
百检网 2021-07-15
标准号:BS ISO 16063-15-2006
中文标准名称:振动和冲击传感器的校准方法.用激光干涉测量法进行初级振动角校准
英文标准名称:Methods for the calibration of vibration and shock transducers - Primary angular vibration calibration by laser interferometry
标准类型:Z32
发布日期:2006/9/29 12:00:00
实施日期:2006/9/29 12:00:00
中国标准分类号:Z32
国际标准分类号:17.160
适用范围:This part of ISO 16063 specifies the instrumentation and procedures used for primary angular vibration calibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotational angle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complex sensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in this part of ISO 16063 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angular transducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angular acceleration. It is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to 1 000 rad/s2 (frequency-dependent). These ranges are covered with the uncertainty of measurement specified in Clause 3. Calibration frequencies lower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) and angular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3B specified in this part of ISO 16063, in conjunction with an appropriate low-frequency angular vibration generator. Method 1A (cf. Clause 8: fringe-counting, interferometer type A) and method 1B (cf. Clause 8: fringe-counting, interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequency range of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (cf. Clause 9: minimum-point method, interferometer type A) and method 2B (cf. Clause 9: minimum-point method, interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to 1,6 kHz. Method 3A (cf. Clause 10: sine-approximation method, interferometer type A) and method 3B (cf. Clause 10: sine-approximation method, interferometer type B) can be used for magnitude of sensitivity and phase calibration in the frequency range of 1 Hz to 1,6 kHz. Methods 1A, 1B and 3A, 3B provide for calibrations at fixed angular acceleration amplitudes at various frequencies. Methods 2A and 2B require calibrations at fixed rotational angle amplitudes (angular velocity amplitude and angular acceleration amplitude vary with frequency).
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;