SAE AS 4851A-2005 绝缘电线的相对热时效和温度指数

百检网 2021-07-20
标准号:SAE AS 4851A-2005
中文标准名称:绝缘电线的相对热时效和温度指数
英文标准名称:Relative Thermal Life and Temperature Index for Insulated Electric Wire
标准类型:V40
发布日期:2005/3/1 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:V40
国际标准分类号:49.060
引用标准:ASTM D 3032-2004;IEEE 98-2002;IEEE 101-1987
适用范围:This test method provides performance data on candidate insulation systems as a function of time and temperature. These data give engineering information on the wire insulation candidate relative to the performance of materials already in use with a backlog of experience. These tests expose candidate insulation systems to a wide range of temperatures for short and long periods of time, while measuring the degradation of its physical properties. For aerospace use, end-point proof tests include mandrel bend, water soak, and dielectric integrity. The thermal rating of an insulation system describes the quantitative relation of life of an insulation system to the temperature and time of exposure. The end of life is defined by the mechanical/electrical loss of integrity of the insulation system after exposure. A Temperature Index (TI) is then assigned based on temperatures and times recorded during the test. It should be noted that the Index is based upon the time at which 50% of the samples have failed. A related quantity is Relative Temperature Index (RTI) and is obtained when a candidate insulation system is simultaneously tested with a known insulation system using identical conditions (e.g., same temperatures, time intervals, and oven). RTI has been found to be more meaningful than TI since it is less affected by the variations in test conditions and procedures. Also included in this document is an extensive appendix to assist the user in performing and interpreting this test. Included in the appendix is an example which provides greater detail for those who have not previously run this test. This type of detail is not included in any of the referenced documents. This test method serves several purposes. Initial qualification of new aerospace wires to specifications for both commercial and military users may be established by using the TI and RTI. Also, it provides engineering information data for assigning operating or rating temperatures for a specific insulated wire. The high temperature test may be used to statistically compare the thermal performance data of a lot of wire with the original test data. The high temperature test is not recommended for use in continuing production quality control procedures until empirical evidence shows that the high temperature test or another analytical procedure, such as a thermogravemetric test, can accurately provide quality control testing information. This test method is primarily based on the degradation of the wire insulation, which tends to follow the Arrhenius relationship with respect to time and temperature. This test method, however, does not address, in and of itself, all mechanisms which may occur to degrade the insulation, nor does it imply that all degradation follow this relationship.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司