BS EN 60976-2007 医疗电气设备.医疗电子加速器.功能的特性特征

百检网 2021-07-20
标准号:BS EN 60976-2007
中文标准名称:医疗电气设备.医疗电子加速器.功能的特性特征
英文标准名称:Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
标准类型:C43
发布日期:2008/4/30 12:00:00
实施日期:2004/3/30 12:00:00
中国标准分类号:C43
国际标准分类号:11.040.50; 13.280
引用标准:IEC 60580-2000;IEC 60601-1-2005;IEC 60601-2-1-1998;IEC 60788-2004;IEC 60977;IEC 61217;IEC 61223-1-1993
适用范围:This International Standard applies to medical ELECTRON ACCELERATORS when used, fortherapy purposes, in human medical practice.This standard applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM ofeither X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeVat maximum ABSORBED DOSE RATES between 0,001 Gy s–1 and 1 Gy s–1 at 1 m from theRADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from theRADIATION SOURCE.The present standard describes measurements and test procedures to be performed by theMANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR butdoes not specify ACCEPTANCE TESTS to be performed after installation at the purchaser's site.The accompanying report, IEC 60977, however, does suggest that many of the testprocedures are appropriate for ACCEPTANCE TESTS.The measurement conditions described in the present standard differ from those previously inuse. This applies particularly to the PHANTOM position for measurements and themeasurement of distances from the ISOCENTRE. These new conditions should be substitutedfor and not be added to previous methods.This standard specifies test procedures for the determination and disclosure of functionalperformance characteristics, knowledge of which is deemed necessary for proper applicationand use of a medical ELECTRON ACCELERATOR and which are to be declared in theACCOMPANYING DOCUMENTS together with the greatest deviation or variation to be expectedunder specific conditions in NORMAL USE. A format for presentation of functional performancevalues is given in Annex A.It is recognized that inaccuracies in the test methods must be allowed for when assessingperformance. However, it was not felt to be advisable to combine the errors into an overallperformance tolerance but to keep them separate in the expectation that more accurate testmethods will be evolved.It is not intended that this standard should in any way inhibit the future development of newdesigns of equipment which may have operating modes and parameters different from thosedescribed herein, provided that such equipment achieves equivalent levels of performance forthe TREATMENT of PATIENTS.Except where otherwise stated this standard assumes that the medical ELECTRONACCELERATORS have an ISOCENTRIC GANTRY. Where the equipment is non-isocentric, thedescription of performance and test methods may need to be suitably adapted.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司