BS EN 60601-2-39-2008 医疗电气设备.腹膜透析设备的基本安全和重要性能的特殊要求

百检网 2021-07-20
标准号:BS EN 60601-2-39-2008
中文标准名称:医疗电气设备.腹膜透析设备的基本安全和重要性能的特殊要求
英文标准名称:Medical electrical equipment — Part 2-39: Particular requirements for basic safety and essential performance of peritoneal dialysis equipment
标准类型:C37
发布日期:2009/3/31 12:00:00
实施日期:2009/3/31 12:00:00
中国标准分类号:C37
国际标准分类号:11.040.99
引用标准:IEC 60601-1-9-2007;IEC 60601-1-10-2007
适用范围:This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE ofPERITONEAL DIALYSIS ME EQUIPMENT as defined in 201.3.208, hereafter referred to asPD EQUIPMENT. It applies to PD EQUIPMENT intended for use either by medical staff or under thesupervision of medical experts, including PD EQUIPMENT operated by the PATIENT, regardless ofwhether the PD EQUIPMENT is used in a hospital or domestic environment.If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or toME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not thecase, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS withinthe scope of this standard are not covered by specific requirements in this standard except in7.2.13 and 8.4.1 of the general standard.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司