BS EN 303-6-2000 供暖锅炉.带强制通风燃烧嘴器的供暖锅炉.标称热输入量不超过70kw的用雾化油燃烧炉的组合式锅炉的家用热水供热特定要求
百检网 2021-08-02
标准号:BS EN 303-6-2000
中文标准名称:供暖锅炉.带强制通风燃烧嘴器的供暖锅炉.标称热输入量不超过70kw的用雾化油燃烧炉的组合式锅炉的家用热水供热特定要求
英文标准名称:Heating boilers - Heating boilers with forced draught burners - Specific requirements for the domestic hot water operation of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
标准类型:J98
发布日期:2000/5/15 12:00:00
实施日期:2000/5/15 12:00:00
中国标准分类号:J98
国际标准分类号:91.140.10;91.140.65
适用范围:This standard supplements EN 303-1, EN 303-2, EN 303-4 and EN 304/A1 hereafter called boiler standards. It specifies the supplementary requirements and tests for the construction, safety, rational use of energy, fitness for purpose, classification and marking related to the domestic hot water operation of oil-fired combination boilers of nominal heat output not exceeding 70 kW.
The domestic hot water is produced on either the instantaneous or storage principle. The domestic hot water production is integrated or coupled, the whole being marketed as a single unit.
This standard does not apply to appliances which operate independently of each other - a boiler and a water heater -even if they have a common flue. Neither does the standard apply to a boiler and water storage tank which are not included within the same casing.