SIS SS-ISO 226-1988 声学.普通等响度级别升降曲线
百检网 2021-08-03
标准号:SIS SS-ISO 226-1988
中文标准名称:声学.普通等响度级别升降曲线
英文标准名称:Acoustics — Normal equal-loudness level contours
发布日期:1988/12/25 12:00:00
实施日期:1999/12/31 12:00:00
适用范围:This International Standard specifies the relations existing, for the condition of equal-loudness level, between the sound pressure levels and frequencies of pure (sinusoidal) continuous tones in the following conditions :a) the source of sound is directly in front of the listener (frontal incidence);b) the sound field in the absence of the listener consists of a free progressive plane wave;c) the sound pressure level is measured in the free progressive plane wave in the absence of the listener;d) the listening is binaural;e) tne conditions of equal-loudness level are determined by the modal value of the judgements of an adequately large group of listeners;f) the listeners are otologically normal persons in the age group from 18 to 30 years inclusive.The relations are expressed by means of an equation in bilinear form, with the sound pressure level as the independent variable and the loudness level as the dependent variable, for the pre-ferred frequencies in the one-third octave series from 20 to 12 500 Hz inclusive.NOTES1 In accordance with convention, the reference dependent variable is taken to be the sound pressure level of a 1 000 Hz tone, i.e. the loudness level expressed in phons. However, the form of the equation remains unchanged (but with transformed coefficients) if the variables are interchanged or if a tone of another frequency in the preferred one-third octave series is taken as the reference.2 The data in this International Standard are approximately equal to equal-loudness level relations between narrow bands of random noise, not exceeding the auditory critical bandwidth.3 Without extrapolation of the experimental data, the upper limit of the frequency range could not be extended to the next preferred frequency in the one-third octave series. For further information regarding the range from 12 500 to 15 000 Hz, see 111.Graphical and short tabular presentations of the relations are given in annexes A and B.Annex C specifies the correction to be applied to obtain the equal-loudness level relations for narrow bands of random noise in a diffuse sound field and the resulting equal-loudness level function.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;