BS EN 61280-4-4-2006 光纤通信子系统基本试验程序.光缆设施和链路.已安装链路的偏振模式色散测量

百检网 2021-08-04
标准号:BS EN 61280-4-4-2006
中文标准名称:光纤通信子系统基本试验程序.光缆设施和链路.已安装链路的偏振模式色散测量
英文标准名称:Fibre optic communication subsystem basic test procedures - Cable plants and links - Polarization mode dispersion measurement for installed links
标准类型:M33
发布日期:2006/5/31 12:00:00
实施日期:2006/5/31 12:00:00
中国标准分类号:M33
国际标准分类号:33.180.01
适用范围:This part of IEC 61280 provides uniform methods of measuring polarization mode dispersion(PMD) of single-mode installed links. An installed link is the optical path between transmitterand receiver, or a portion of that optical path. These measurements may be used to assessthe suitability of a given link for high bit rate applications or to provide insight on therelationships of various related transmission attributes. The principles of this document arealigned with those of the optical fibre and optical fibre cable test method, IEC 60793-1-48 (seeBibliography), which focuses on aspects related to the measurement of factory lengths.Instead, this document focuses on the measurement methods and requirements for measuringlong lengths that might be installed – and that might also include other optical elements, suchas amplifiers, DWDM components, multiplexers, etc.PMD is a statistical parameter. The reproducibility of measurements depends on the particularmethod, but is limited also by the PMD level of the link. Gisin [3]5) derived a theoretical limit tothis reproducibility, by assuming an infinite range of measured wavelengths and idealmeasurement conditions.With the exception of Method D, all methods in this document may be used to measure thePMD in the gain band of links that include pumped optical amplifiers. For these links,amplified spontaneous emission (ASE) noise can generate depolarized spectral energy in theneighbourhood of the measurement wavelength. This will, in general, reduce the accuracy ofthe measurement. For Methods A, B, C, E and F, this effect can be moderated byimplementing an optical or electrical filter at the receive end. However, optical filtering will notremove the ASE right under the signal spectrum. The accuracy will then be limited by a lowerdegree of polarization (DOP), if the spectral width of the filter cannot be sufficiently reducedas with a broadband source. Lower DOP may require the signal to be integrated longer to bemeaningful or the result will become too noisy and interpretation will be erroneous.None of the methods is suitable for measuring the PMD of links with polarization dependentloss (PDL) in excess of 10 dB. Links with PDL values less than 1 dB can be measured withreasonable accuracy. Measurement accuracy may be compromised by the presence of PDL inexcess of 1 dB.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司