BS ISO 15561-1999 重铬酸盐剂量测定系统的使用规程
百检网 2021-08-04
标准号:BS ISO 15561-1999
中文标准名称:重铬酸盐剂量测定系统的使用规程
英文标准名称:Practice for use of a dichromate dosimetry system
标准类型:F81
发布日期:1999/9/15 12:00:00
实施日期:1999/9/15 12:00:00
中国标准分类号:F81
国际标准分类号:17.240
适用范围:1 This practice covers the preparation, testing, and procedure for using the acidic aqueous silver dichromate dosimetry system to measure absorbed dose in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the dichromate system. It is classified as a reference standard dosimetry system (see Guide E 1261). 2 This practice describes the spectrophotometric anal-ysis procedures for the dichromate system. 3 This practice applies only to γ-rays, x-rays, and high energy electrons. 4 This practice applies provided the following condi-tions are satisfied: 4.1 The absorbed dose range is from 2 × 10 to 5 × 10 Gy. 4.2 The absorbed dose rate does not exceed 600 Gy/ pulse with a pulse repetition rate not to exceed 12.5 Hz, or does not exceed an equivalent dose rate of 7.5 kGy/s from continuous sources (1). 4.3 For radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV. —The lower energy limits given are appropriate for a cylindrical dosimeter ampoule of 12 mm diameter. Corrections for displacement effects and dose gradient across the ampoule may be required for electron beams (2). The dichromate system may be used at lower energies by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35). 4.4 The irradiation temperature of the dosimeter shall be above 0℃ and should be below 80℃. Note 2—The temperature coefficient of dosimeter response is known only in the range of 5℃ to 50℃ (see 10.1.8). Use outside this range is not recommended. 5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Note 6.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;