IEC 61788-1-2006 超导性.第1部分:临界电流测量.铌-钛复合超导体的临界直流电流

百检网 2021-08-05
标准号:IEC 61788-1-2006
中文标准名称:超导性.第1部分:临界电流测量.铌-钛复合超导体的临界直流电流
英文标准名称:Superconductivity - Part 1: Critical current measurement - DC critical current of Nb-Ti composite superconductors
标准类型:K10
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:K10
国际标准分类号:17.220;29.050
适用范围:This part of IEC 61788 covers a test method for the determination of the d.c. critical current ofeither Cu/Nb-Ti composite superconductors that have a copper/superconductor ratio largerthan 1 or Cu/Cu-Ni/Nb-Ti wires that have a copper/superconductor ratio larger than 0,9 and acopper alloy (Cu-Ni)/superconductor ratio larger than 0,2, where the diameter of Nb-Tisuperconducting filaments is larger than 1 μm. The changes for the Cu/Cu-Ni/Nb-Ti aredescribed in Annex C. The Cu-Ni uses all of the main part of the standard with the exceptionslisted in Annex C that replace (and in some cases are counter to) some of the steps in themain text.This method is intended for use with superconductors that have critical currents less than1 000 A and n-values larger than 12, under standard test conditions and at magnetic fieldsless than or equal to 0,7 of the upper critical magnetic field. The test specimen is immersed ina liquid helium bath at a known temperature during testing. The test conductor has amonolithic structure with a round or rectangular cross-sectional area that is less than 2 mm2.The specimen geometry used in this test method is an inductively coiled specimen. Deviationsfrom this test method that are allowed for routine tests and other specific restrictions aregiven in this standard.Test conductors with critical currents above 1 000 A or cross-sectional areas greater than2 mm2 could be measured with the present method with an anticipated increase in uncertaintyand a more significant self-field effect (see Annex B). Other, more specialized, specimen testgeometries may be more appropriate for larger conductor testing which have been omittedfrom this present standard for simplicity and to retain a lower uncertainty.The test method given in this standard is expected to apply to other superconductingcomposite wires after some appropriate modifications.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司