IEC 61540-1997 电气附件.家用和类似用途无综合过电流保护的便携式剩余电流器件(PRCDs)

百检网 2021-08-05
标准号:IEC 61540-1997
中文标准名称:电气附件.家用和类似用途无综合过电流保护的便携式剩余电流器件(PRCDs)
英文标准名称:Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
标准类型:Y60
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:Y60
国际标准分类号:29.120.50
适用范围:This International Standard applies to portable devices for household and similar uses (hereafter referred to as portable residual current devices (PRCDs) consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection, functionally independent of, or functionally dependent on, line voltage. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16 A for rated voltages not exceeding 250 V a.c., or for rated current not exceeding 32 A for rated voltages not exceeding 130 V a.c. to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. They ensure tripping in case of residual alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising (see 8.15). Plugs and socket-outlets will comply with the relevant standards. This standard applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. They are not intended to be used as parts of fixed installations. Their connecting means may be plugs, socket-outlets, terminals or cords. NOTES 1 The requirements for PRCDs are in line with the general requirements of IEC 61008-1. PRCDs are essentially intended to be operated by unskilled persons and designed not to require maintenance. They may be submitted for certification purposes. 2 The RCD part of the PRCD is not intended to provide isolation which may be provided by the plug. 3 The use of an integral fuse is permitted, if necessary, for the relevant plug and socket-outlet system. 4 In Australia and in Germany, PRCDs switching also the PE circuit are in use. Such devices are not covered by this standard. The requirements of this standard apply for environmental conditions as defined in 7.1. Additional requirements may be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this standard. The present standard does not contain additional requirements for PRCDs without earthing contacts for which specific requirements may apply. It may, however, be used as a guide for such devices which are intended to be used only with Class II appliances. The present standard does not apply to PRCDs providing the additional function of detecting faults on the supply side and avoiding the closing of the PRCD on a faulty supply circuit.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司