IEC/TR3 61859-1997 放射治疗设备机房设计导则
百检网 2021-08-05
标准号:IEC/TR3 61859-1997
中文标准名称:放射治疗设备机房设计导则
英文标准名称:Guidelines for radiotherapy treatment rooms design
标准类型:C43
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:C43
国际标准分类号:11.040.50;13.280
适用范围:This technical report applies only to those aspects of the installation ensuring the safety of the patient, the operator and other persons during the RADIOTHERAPY EQUIPMENT use. General construction requirements are not addressed in this technical report.
The installations considered in this technical report are those in which are located ARADIOTHERAPY EQUIPMENT delivering IONIZING RADIATION used for therapeutic purpose, such as
MEDICAL ELECTRON ACCELERATORS, GAMMA BEAM THERAPY EQUIPMENT
AND GAMMA-RAY
AFTERLOADING EQUIPMENT. RADIOTHERAPY SIMULATOR installations are not included in this technical report.
A particular RADIOTHERAPY EQUIPMENT installation may generally consist of several rooms, such as:
- the TREATMENT ROOM in which the RADIATION BEAM is emitted and in which the PATIENT is located during the IRRADIATION, including all enclosed spaces where a person could remain inadvertently during the IRRADIATION;
- the control room in which the TREATMENT CONTROL PANEL is located and from which the OPERATOR controls the IRRADIATION and other functions of the RADIOTHERAPY EQUIPMENT;
- other rooms which may contain other parts of the RADIOTHERAPY EQUIPMENT, but where IRRADIATION is not carried out.