AAMI/ISO 14160-1998 动物性成分复合材料的一次性使用医疗器械的消毒.利用液体化学消毒剂进行消毒的常规控制和确认

百检网 2021-08-05
标准号:AAMI/ISO 14160-1998
中文标准名称:动物性成分复合材料的一次性使用医疗器械的消毒.利用液体化学消毒剂进行消毒的常规控制和确认
英文标准名称:Sterilization of single-use medical devices incorporating materials of animal origin - Validation and routine control of sterilization by liquid chemical sterilants
标准类型:C30
发布日期:1998/7/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:C30
适用范围:This International Standard specifies requirements for the development, validation, process control and monitoring of the sterilization, by the use of liquid chemical sterilants, of single-use medical devices comprising, in whole or in part, materials of animal origin.This International Standard does not apply to material of human origin.This International Standard does not describe a quality assurance system for the control of all stages of manufacture.NOTE 1 Attention is drawn to the standards for quality systems (see ISO 9001 and ISO 13485 or ISO 9002 and ISO 13488) which can be used in the control of all stages of manufacture including the sterilization process.This International Standard does not describe tests to establish the effects of any chosen sterilization method upon the fitness for use of the medical device.NOTE 2 Such testing is a crucial part of the design and development of a medical device.This International Standard does not describe methods for the validation of the inactivation of viruses.NOTE 3 In developing a method for processing medical devices containing materials of animal origin, consideration of the effects of liquid chemical sterilization on potential viral contaminants will also be necessary because of the source of materials used in themanufacture of these particular medical devices. The importance of validation of viral inactivation for processes within the scope of this International Standard is recognized. This aspect is excluded from this International Standard; a separate European Standard is inpreparation (EN 12442-3).NOTE 4 Liquid chemical sterilants traditionally employed to sterilize animal tissues in medical devices may not be effective in inactivating the causative agents of transmissible spongiform encephalopathies such as bovine spongiform encephalopathy (BSE), or scrapie. Satisfactory validation in accordance with this International Standard should not be assumed to demonstrate inactivation ofinfective agents of this type.This International Standard does not cover the level of residual sterilant within medical devices.NOTE 5 ISO 14538 is concerned with this issue.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司