BS EN 12544-2-2000 无损检验.X射线管电压的测量和评估.用厚滤膜法进行连续检验
百检网 2021-07-16
标准号:BS EN 12544-2-2000
中文标准名称:无损检验.X射线管电压的测量和评估.用厚滤膜法进行连续检验
英文标准名称:Non-destructive testing - Measurement and evaluation of the X-ray tube voltage - Constancy check by the thick filter method
标准类型:H26
发布日期:2000/6/15 12:00:00
实施日期:2000/6/15 12:00:00
中国标准分类号:H26
国际标准分类号:19.100
适用范围:This standard specifies a constancy check of a X-ray system where mainly the X-ray voltage is checked and also the tube current and the constitution of the target which can be changing due to ageing of the tube.
The thick filter method is based on a measurement of the dose rate behind a defined thick filter using defined distances between the X-ray tube, the filter and the measuring device.
This method is very sensitive to changes of the voltage, but it does not provide an absolute value for X-ray tube voltage. Therefore, a reference value is needed and, it is recommended to find this reference, for example, within the acceptance test of the system.
The thick filter method is a rather simple technique and may be applied by the operator of an X-ray system to performregularly a constancy check of the system.
The method can also be applied for consistency checks after changing components which may affect the X-ray tube voltage.
This method can be applied for all types of X-ray systems, i.e. for constant potential, half wave and impulse wave generators with a tube current larger than 1 mA.