ANSI/ASTM D2561-1995 吹模聚乙烯容器耐环境应力断裂试验方法(08.02)

百检网 2021-07-16
标准号:ANSI/ASTM D2561-1995
中文标准名称:吹模聚乙烯容器耐环境应力断裂试验方法(08.02)
英文标准名称:Test Method for Environmental Stress-Crack Resistance of Blow-Molded Polyethylene Containers (08.02)
标准类型:G31
发布日期:1999/12/31 12:00:00
实施日期:2001/6/10 12:00:00
中国标准分类号:G31
国际标准分类号:83.080.20;83.140.99
适用范围:Under certain conditions of stress, and in the presence of environments such as soaps, wetting agents, oils, or detergents, blow-molded polyethylene containers may exhibit mechanical failure by cracking at stresses appreciably below those that would cause cracking in the absence of these environments. This test method measures the environmental stress- crack resistance of containers, which is the summation of the influence of container design, resin, blow-molding conditions, post treatment, or other factors that can affect this property. Three procedures are provided as follows: Procedure A, Stress-Crack Resistance of Containers to Commercial Liquids -This procedure is particularly useful for determining the effect of container design on stress-crack resistance or the stress-crack resistance of a proposed commercial package containing a proprietary liquid product. Procedure B, Stress-Crack Resistance of a Specific Container to Polyoxyethylated Nonylphenol, a Stress-Cracking Agent -The conditions of test described in this procedure are designed for testing containers made from Type III polyethylene Specification D1248. Therefore, this procedure is recommended for containers made from Type III polyethylene only. This procedure is particularly useful for determining the effect of resin on the stress-crack resistance of the container. Procedure C, Controlled Elevated Pressure Stress-Crack Resistance of a Specific Container to Polyoxyethylated Nonylphenol, a Stress-Cracking Agent -The internal pressure is controlled at a constant elevated level. These procedures are not designed to test the propensity for environmental stress cracking in the neck of containers, such as when the neck is subjected to a controlled strain by inserting a plug. The values stated in SI units are to be regarded as the standard. Note 1 -There is no similar or equivalent ISO standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8 and Notes 1 and 9.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司