BS 476-24-1987 建筑材料和结构的燃烧试验.第24部分:通风管道耐火性的测定方法

百检网 2021-07-16
标准号:BS 476-24-1987
中文标准名称:建筑材料和结构的燃烧试验.第24部分:通风管道耐火性的测定方法
英文标准名称:Fire tests on building materials and structures - Method for determination of the fire resistance of ventilation ducts
标准类型:Q10;P16
发布日期:1987/5/29 12:00:00
实施日期:1987/5/29 12:00:00
中国标准分类号:Q10;P16
国际标准分类号:13.220.50;91.140.30
适用范围:1 This International Standard specifies a method of test and criteria for the determination of the fire resistance of ver-tical and horizontal ventilation ducts under standardized fire conditions. 2 The general purpose of this test is to measure the ability of a representative duct or duct assembly to resist the spread of fire from one fire compartment to another without the aid of fire dampers. 3 It is applicable to vertical and horizontal ducts, with or without branches, taking into account joints, air supply and ex-haust openings, as well as suspension devices, etc. 4 This International Standard is not applicable to: a) ducts above fire-resisting suspended ceilings (horizon-tal membranes) in those cases where the ducts rely for their fire resistance on the performance of the ceiling; NOTE — Other tests are necessary for these ducts. b) ducts containing fire dampers at points where they pass through fire separations. NOTE — In order to assess the fire resistance of fire dampers, other tests are required. A method of test for fire dampers is under con-sideration as a subject for a future International Standard. 5 This International Standard is not appropriate for the following ducts unless the further criteria described in the an-nex are established to the satisfaction of the appropriate authority: a) ducts of materials which are extremely sensitive to ther-mal shock; NOTE — Thermal shock may affect such ducts in a way that would differ from the effect in this test, but the test may still be used where it can be established that sensitivity to thermal shock is within acceptable limits. b) smoke outlet ducts; NOTE — These ducts need to retain their integrity and cross-sectional area under fire conditions. Consequently criteria for ac-ceptance additional to those given in this International Standard are required. This International Standard is only applicable, therefore, to smoke outlet ducts if the criteria for integrity failure of a representative smoke outlet duct within the furnace and the loss of retention of cross-sectional area of such ducts are agreed between all parties concerned and are investigated and reported (see the annex). c) ducts lined on the inside with combustible material or which in practice may accumulate combustible deposits on their inside face (such as kitchen extract ducts). NOTE — Additional criteria regarding the insulation performance of the duct are required in this case (see the annex). 6 This International Standard does not take into considera-tion the effect of impact shock loading on ducts due to the col-lapse of supporting or adjacent structural members or other components, or of impact- or thermal shock loading resulting from the application of a water (hose) stream. NOTE — The method described in this International Standard should be used solely to measure and describe the properties of ducts and their supports in response to heat and flame under controlled laboratory conditions and should not by itself be con-sidered or used for the description, appraisal or regulation of the fire hazard of such ducts or supports under actual fire con-ditions.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司