IEC 62335-2008 断路器.I级绝缘车辆和蓄电池车辆设施用便携式剩余电流装置的开关保护用地线
百检网 2021-07-20
标准号:IEC 62335-2008
中文标准名称:断路器.I级绝缘车辆和蓄电池车辆设施用便携式剩余电流装置的开关保护用地线
英文标准名称:Circuit breakers - Switched protective earth portable residual current devices for class I and battery powered vehicle applications
标准类型:K31
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:K31
国际标准分类号:29.120.50
引用标准:IEC 60065;IEC 60068-2-30;IEC 60068-3-4;IEC 60112;IEC 60227;IEC 60245;IEC 60269-1;IEC 60364;CISPR 14;IEC 60384-14;IEC 60417-DB;IEC 60529;IEC 60664-3;IEC 60695-2-10;IEC 60695-2-11;IEC 60884-1-2002;IEC 60898;IEC 61008-1-1996;IEC 61249-2;IEC 61540-1997;IEC 61
适用范围:This International Standard applies to portable devices intended for use with vehicles havingclass 1 insulation and battery powered vehicle applications having battery charging units.They have a switched protective earth (SPE) and hereafter are referred to as SPE-PRCDs.The SPE-PRCD consists of a plug, a residual current device (RCD) and a portable socketoutlet.This standard applies to portable devices performing simultaneously the functions of detectionof the residual current, of comparison of the value of this current with the residual operatingvalue and of opening of the protected circuit when the residual current exceeds this value.In addition to the RCD function, the SPE-PRCDs address incorrect supply connectionsresulting in a hazardous live PE and/or supply failure (for example: loss of supply PE or lossof supply N). These SPE-PRCDs are intended for application only on TN and TT systems.These SPE-PRCDs will not operate if used on IT or other unearthed systems such as isolatedwinding generator or isolating transformer. These SPE-PRCDs, due to the PE effectivelybeing an open supply conductor, will not function to close the contacts on an IT system.NOTE 1 For applications where due to the supply system a SPE-PRCD cannot operate a PRCD (according toIEC 61540) may be used.SPE-PRCDs are not required to incorporate overcurrent protection.SPE-PRCDs are intended to be supplied from single-phase or two-phase circuits with ratedcurrents not exceeding 16 A for rated voltages not exceeding 250 V a.c., or with rated currentnot exceeding 32 A for rated voltages not exceeding 130 V a.c. to earth.SPE-PRCD have a rated residual operating current not exceeding 30 mA and are intended toprovide additional protection against shock hazard in case of direct contact on the circuitdownstream of the SPE-PRCD. This protection is additional to that provided by the fixedinstallations. They will not detect a direct contact of a person from line to neutral and do notsubstitute for safe installation requirements.Plugs and socket-outlets will comply with the relevant standards. The use of an integral fuseis permitted, if necessary, for the relevant plug and socket-outlet system.SPE-PRCD are not intended to be used as part of a fixed installation or permanentlyconnected to equipment. They should be connected by a plug and the outlet should be aportable socket outlet.If a SPE-PRCD of the incorrect type is used (example an LNSE instead of an LLSE) it shouldcontinue to protect.SPE-PRCDs including batteries are not covered by this standard.Additional requirements may be necessary for SPE-PRCDs used in locations having severeenvironmental conditions.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;