BS EN 62464-1-2007 医疗成象磁共振设备.成像质量基本参数的测定
百检网 2021-08-04
标准号:BS EN 62464-1-2007
中文标准名称:医疗成象磁共振设备.成像质量基本参数的测定
英文标准名称:Magnetic resonance equipment for medical imaging - Determination of essential image quality parameters
标准类型:C43
发布日期:2007/7/31 12:00:00
实施日期:2007/7/31 12:00:00
中国标准分类号:C43
国际标准分类号:11.040.50
引用标准:IEC 60788
适用范围:This international standard specifies measurement procedures for the determination of manyessential medical MR EQUIPMENT image quality parameters. Measurement procedures asaddressed in this standard are suitable for:- quality assessment in the ACCEPTANCE TEST;- quality assurance in the CONSTANCY TEST.In addition, the measurement procedures specified in this standard may also be useful fortype tests, although that is not an objective of this standard.This standard does not address:- required levels of performance for ACCEPTANCE TEST and CONSTANCY TEST;- image quality assessment of high field MR EQUIPMENT greater than 4 T, if not otherwisestated;- image quality affected by MR-compatibility issues;- special diagnostic procedures such as flow imaging, perfusion, diffusion, radiotherapy andimage-guided therapy applications;- type tests.The scope of this standard is also limited to measuring image quality characteristics in TESTDEVICES, not in PATIENT images.The measurement procedures specified in this standard are directed to:a) MANUFACTURERS, who can demonstrate compliance by performing acceptance andconstancy methods as described by this standard,b) test houses, which can confirm performance of MR EQUIPMENT using methods described inthis standard,c) regulatory authorities, who can reference this standard, andd) RESPONSIBLE ORGANISATIONS who want to perform ACCEPTANCE and CONSTANCY TESTSusing methods described in this standard.The essential image quality parameters and measurement methodologies defined in thisstandard are:- SIGNAL-TO-NOISE RATIO,- UNIFORMITY,- SLICE THICKNESS and SLICE PROFILE,- GEOMETRIC DISTORTION,- SPATIAL RESOLUTION, and- ghosting.This standard describes the preferred measurement procedures. It also describes alternativemethods in Annex A. The preferred test methods may be substituted with the alternativemethods. If necessary, other methods not described in this standard may be used, providedthese other test methods are documented and validated against the methods described in thestandard. Validation of other test methods requires an analysis of test sensitivity to the sameparameter of interest and an analysis of the insensitivity of the test to other unrelatedparameters and should demonstrate a similar, or better, level of sensitivity to the sameparameter of interest and a similar, or better, level of robustness against unrelatedparameters. All methods shall produce quantitative results.The rationale to the preferred and alternate methods, and their pitfalls, are described inAnnex B.This standard also presents requirements for CONSTANCY TESTS suitable for MR EQUIPMENTquality assurance programs concerning essential image quality parameters. There are nopreferred CONSTANCY TEST methods, to provide flexibility in using existing automatedprocedures where available, but suggested examples of test methods are found in Annex A. Ifnecessary, other CONSTANCY TEST methods not described in this standard may be used. Sincethe needs of RESPONSIBLE ORGANISATIONS' quality assurance programs may vary, RESPONSIBLEORGANISATIONS are encouraged to determine the necessary scope of tests, quality of thetests, and the sensitivity of the data analysis etc. This standard places an emphasis onconsistently repeatable, automated measuring tools that facilitate trend analysis and thefrequent quick testing of a small set of important parameters which are sensitive to the overalloperating characteristics of the MR EQUIPMENT.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;