BS 7846-2009 电缆.受火影响时排放少量烟和腐蚀气体的600/1000 V热固绝缘铠装耐火电缆.规范

百检网 2021-08-04
标准号:BS 7846-2009
中文标准名称:电缆.受火影响时排放少量烟和腐蚀气体的600/1000 V热固绝缘铠装耐火电缆.规范
英文标准名称:Electric cables - Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire - Specification
标准类型:K13
发布日期:2009/9/30 12:00:00
实施日期:2009/9/30 12:00:00
中国标准分类号:K13
国际标准分类号:29.060.20
引用标准:BS 5099;BS 6387-1994;BS 7655-1.2;BS 7655-1.3;BS 7655-6.1;BS 8491-2008;BS 10244-2-2009;BS EN 50266-2-4-2001;BS EN 50267-2-1;BS EN 50363-5;BS EN 60228;BS EN 60332-1-2-2004;BS EN 60811-1-1;BS EN 60811-1-2-1995+A1-2002;BS EN 60811-1-3;BS EN 61034-2;BS EN 6223
适用范围:This British Standard specifies requirements for construction andperformance, and describes methods of test, for armoured, fire‑resistantcables with thermosetting insulation and of rated voltage 600/1 000 Vand low emission of smoke and corrosive gases when affected by fire.The circuit integrity performance under fire conditions is assessed onthe basis of various tests which either separately measure resistanceto fire, resistance to fire with water spray, and resistance to fire withmechanical shock (Category F2) or in combination measure resistanceto fire with direct mechanical impact and water jet (Categories F30, F60and F120).Cables specified in this standard are intended for use in fixedinstallations in industrial areas, buildings and similar applications,where maintenance of power supply during a fire is required for adefined period of time.NOTE 1 Attention is drawn to the fact that the ability of a given cableto meet a particular category in this standard refers only to the testconditions stated, and the level of performance achieved in a particularinstallation can be influenced by actual installation conditions.Cables covered by this standard have limited evolution of smoke andcorrosive gases when assessed under the fire conditions as specified inBS EN 61034-2 and BS EN 50267-2-1.In this standard, the level of corrosive (and acid) gases is determinedby measurement of hydrochloric acid (HCl) in accordance withBS EN 50267-2-1.The insulation and other components are suitable to permit operationof the cables at a maximum sustained conductor temperature of 90 °Cand for a maximum short-circuit conductor temperature of 250 °C.NOTE 2 Limitation on the temperature of the cables may be imposed insituations where they may be touched.NOTE 3 Due to the relatively high conductor temperature, there is arisk of drying out the surrounding soil causing an increase in thermalresistivity which in turn would lead to the cable temperature rising toa higher value than anticipated. For cable laid directly in the ground, asuitable de-rating factor should be applied or a lower maximum sustainedconductor operating temperature should be assumed to take into accountthe possible effects of soil drying out.NOTE 4 In installations which include cable joints and terminations, theperformance of these accessories should be taken into account in decidingthe maximum operating temperature of the cable.The cables specified in the standard are either steel wire armoured orinterlocked steel tape armoured and sheathed, as follows:a) two-, three-, four- and five-core stranded copper conductor;b) multicore auxiliary stranded copper conductor.Annex A gives recommendations for the selection and operation ofcables while recommendations for the installation of cables are givenin Annex B. Annex C lists the information that should be given with anenquiry or order.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司