BS IEC 61363-1-2002 船舶和移动式及固定式近海装置的电气设施.三相交流短路电流计算程序
百检网 2021-08-04
标准号:BS IEC 61363-1-2002
中文标准名称:船舶和移动式及固定式近海装置的电气设施.三相交流短路电流计算程序
英文标准名称:Electrical installations of ships and mobile and fixed offshore units - Procedures for calculating short-circuit currents in three-phase a.c
标准类型:U60
发布日期:2002/8/14 12:00:00
实施日期:2002/8/14 12:00:00
中国标准分类号:U60
国际标准分类号:47.020.60
适用范围:This International Standard outlines procedures for calculating short-circuit currents that may occur on a marine or offshore a.c. electrical installation. The calculation methods are for use on unmeshed three-phase alternating current systems, a) operating at 50 Hz or 60 Hz; b) having any system voltage specified in IEC 60092-201 table 2; c) having one or more different voltage levels; d) comprising generators, motors (both synchronous and asynchronous), transformers, reactor coils, cables, and converter units; e) having their neutral point connected to the ship's hull through an impedance (designed to limit the short-circuit current flowing to the ship's hull); f) having their neutral point isolated from the ship's hull. The calculation procedures are for a three-phase symmetrical short-circuit condition i.e. three-phase conductors shorted together, or shorted to the ship's hull and for which the short-circuit occurs on all three poles simultaneously. The calculation of short-circuit currents resulting from asymmetric short-circuit conditions can lead to higher aperiodic (d.c.) components of the short-circuit current and is not considered in this standard. The calculating formulae and methods described produce sufficiently accurate results to calculate the short-circuit current during the first 100 ms of a fault condition. They can be used to calculate the short-circuit current for periods longer than 100 ms when calculating on a bus system to which the generators are directly connected. For time periods beyond 100 ms the controlling effects of the system voltage regulators may be predominant. Calculations including the voltage regulator effects are not considered in this standard. The object of this standard is to present formulae for calculating short-circuit currents of the active components of an electrical system and to indicate how such formulae may be simplified when calculating the short-circuit current at various locations on the electrical system. The calculations give estimates of the prospective short-circuit current when the system's active components produce their maximum contribution. The calculating formulae are developed from basic electrical engineering theories relevant to the system components. To simplify the calculation methods yet retain an acceptable level of accuracy in the results, suitable assumptions are outlined and their effects on the calculation results indicated. This standard provides a calculation procedure. It gives guidance on the interpretation and application of simplifying formulae and the corresponding results when applied to the selection of switchgear. The standard is not intended to provide any other information other than the calculation of the short-circuit current which may flow in the network. In order to understand the methods, and consequences of the results, it is assumed that the person responsible for initiating the short-circuit current calculations, is thoroughly familiar with valid electrical engineering fundamentals.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;