DIN EN 14790-2006 固定源排放.管道中水蒸气含量测定
百检网 2021-08-05
标准号:DIN EN 14790-2006
中文标准名称:固定源排放.管道中水蒸气含量测定
英文标准名称:Stationary source emissions - Determination of the water vapour in ducts; English version of DIN EN 14790:2006-04
标准类型:Z60
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:Z60
国际标准分类号:13.040.40
引用标准:ENV 13005;CEN/TS 14793;EN ISO 14956
适用范围:This European Standard describes the condensation/adsorption technique, including the sampling system, todetermine the water vapour concentration in the flue gases emitting to atmosphere from ducts and stacks.This technique is usually used all over Europe for water vapour monitoring. However to be implemented asthe Standard Reference Method (SRM), the user has to demonstrate that the performance characteristics ofthe method are better than the performance criteria defined in this European Standard and that the overalluncertainty of the method is less than + _20 % of the measured value. This European Standard as theStandard Reference Method (SRM) is used for periodic monitoring and for calibration or control of AutomaticMeasuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes.An Alternative Method to this SRM may be used provided that the user can demonstrate equivalenceaccording to the Technical Specification CEN/TS 14793, to the satisfaction of his national accreditation bodyor law.The determination of water vapour is mainly necessary for:-- regulatory purposes, to express the concentration at standard conditions (on dry gas);-- adjust the flow rate for isokinetic sampling, when a dry gas flow rate metering device is used.For both applications, the quantity to be measured is the amount of water present in the gas phase (vapour),which does not include water droplets.This European Standard is applicable in the range from 4 % to 40 % relative humidity and for water vapourconcentration from 29 g/m3 to 250 g/m3 as a wet gas, although for a given temperature the upper limit of themethod is related to the maximum pressure of water in air or in the gas.This European Standard has been evaluated during field tests on waste incineration, co-incineration and largecombustion installations. It has been validated for sampling periods of 30 min in the concentration range of7 % to 26 % volume.In this European Standard all the concentrations are expressed in normal conditions (273 K and 101,3 kPa).NOTE For saturated conditions the condensation/adsorption method is not applicable. Some guidance is given in thisEuropean Standard to deal with flue gas when droplets are present.
百检能给您带来哪些改变?
1、检测行业全覆盖,满足不同的检测;
2、实验室全覆盖,就近分配本地化检测;
3、工程师一对一服务,让检测更精准;
4、免费初检,初检不收取检测费用;
5、自助下单 快递免费上门取样;
6、周期短,费用低,服务周到;
7、拥有CMA、CNAS、CAL等权威资质;
8、检测报告权威有效、中国通用;