DIN EN ISO 7197-2009 神经外科植入物.无菌、一次性使用的脑积水分流管和组件(ISO 7197-2006,包括技术勘误 1-2007);德文版本 EN ISO 7197-2009

百检网 2021-07-20
标准号:DIN EN ISO 7197-2009
中文标准名称:神经外科植入物.无菌、一次性使用的脑积水分流管和组件(ISO 7197-2006,包括技术勘误 1-2007);德文版本 EN ISO 7197-2009
英文标准名称:Neurosurgical implants - Sterile, single-use hydrocephalus shunts and components (ISO 7197:2006, including Cor 1:2007); English version of DIN EN ISO 7197:2009-08
标准类型:C45
发布日期:1999/12/31 12:00:00
实施日期:2009/8/1 12:00:00
中国标准分类号:C45
国际标准分类号:11.040.40
引用标准:ISO 10993-1;ISO 14630-2005;ISO 14971;ASTM F640-1979
适用范围:This International Standard specifies safety and performance requirements for sterile, single-use non-activehydrocephalus shunts and components. This includes the components used in shunts, like valves, tubes andreservoirs.This International Standard gives no recommendation concerning the superiority of a certain type of valve.For manufacturing, it defines the mechanical and technical requirements. This International Standard definesthe technical information of the valve, to be given by the manufacturer. In respect to the different principles ofthe valve types, specific characteristics are defined for each group as declared by the manufacturer.The benefit of this International Standard for the surgeon and the patient is to understand the informationgiven by the manufacturer and to obtain standardized information about the performance of a well workingproduct with new design characteristics. The benefit for the manufacturer is to define the importantrequirements for shunts as a basis for investigations during development as well as for quality control duringmanufacture.This International Standard does not apply to active implants for the treatment of hydrocephalus.

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司